Based on MUC microcontroller (microprocessor control unit)
■ Real-time process / high precision
■ Enhanced monitoring function: monitoring distance up to 400 meters, 3-phase current display, pre-alarm (3DM2/FDM2) action reason description
■ Monitoring function: provided Communication software for use on PC
■ With overheating without current external transformer, current within 32A. Inverse time protection
■ Suitable for three-phase / single-phase motor protection
■ RoHS compliance
■ Digital setting / action cause indication and fault Exclusion
■Auto reset/reset time setting
■ For FDM2/FMZ2, normal protection is guaranteed even if PDM is disco
■ Real-time process / high precision
■ Enhanced monitoring function: monitoring distance up to 400 meters, 3-phase current display, pre-alarm (3DM2/FDM2) action reason description
■ Monitoring function: provided Communication software for use on PC
■ With overheating without current external transformer, current within 32A. Inverse time protection
■ Suitable for three-phase / single-phase motor protection
■ RoHS compliance
■ Digital setting / action cause indication and fault Exclusion
■Auto reset/reset time setting
■ For FDM2/FMZ2, normal protection is guaranteed even if PDM is disco
Protection project | Setting range and conditions | Action time |
Overcurrent | When the current value on the load exceeds the set current value: Setting range: 0.5 to 60 A (definite time limit) 0.5 to 32 A (inverse time limit) |
Time limit: between 0.2 and 30 seconds |
Inverse time limit & overheating inverse time limit: 1~30 Class | ||
Undercurrent | The undercurrent set value cannot exceed or equal to the overcurrent set value when the current value on the load is lower than the set undercurrent value. |
OFF, adjusted between 1 and 10 seconds |
Reverse phase | This option can be used when the phase sequence reciprocal of the three-phase current is used . |
Within 0.15 seconds |
Stall | This value is set to several times the overcurrent set value. It is only suitable for the start-up process and its setting range can be adjusted. 0.5 to 30A: 2 to 8 times to 40A of overcurrent setting value : 2 to 6 times to 60A: 2 to 4 times |
After D-Time time (within 0.5 seconds) |
Stall | This value is set to several times the overcurrent set value. It is only suitable for operation and its setting range can be adjusted. 0.5 to 50A: 1.5 to 5 times to 60A ofthe overcurrent setting value : 1.5 to 4 times |
Adjust between 0.3 and 5 seconds |
Phase imbalance | Condition: Current imbalance ≥ setting imbalance % Setting range: 10 to 50% imbalance |
Adjust between 1 and 10 seconds |
Ground | Condition: Ground current setting range when the ground current setting value is exceeded : OFF, 0.05-10A |
Adjust between 0.5 and 5 seconds — 3MZ2/FMZ2 only — |
Overcurrent | Rated setting range (A) | Definite time limit: 0.5~60A: More than 60A need to use external transformer | ||||
Inverse time limit: 0.5~60A: More than 32A need to use external transformer | ||||||
Undercurrent | Rated setting range (A) | 0.5A ~ less than the OC setting | ||||
Action time characteristic | Definite time/inverse time limit | |||||
time setting | Definite time limit | D-time | 0~200 seconds | |||
O-time | 0.2~30 seconds | |||||
Inverse time limit (cLS) | 1~30 classes | |||||
Ground D-time (Edt) | 0~30s (3MZ2/FMZ2) | |||||
Ground O-time (Et) | 0.05~10s (3MZ2/FMZ2) | |||||
Automatic reset | 0.5s~20 minutes. | |||||
Reset mode | Manual reset / electric reset / automatic reset | |||||
Control voltage | Voltage | 100~240VAC/DC (85% ~ 110%, Free voltage), 24VAC/DC (±5%). | ||||
frequency | 50/60Hz | |||||
Power consumption | Less than 7VA | |||||
Output | capacity | 3A/250VAC resistance. | ||||
structure | 1a1b : OC or GR | |||||
1a : AL | ||||||
display | 7-segment LED | 3-phase current value, ground current, trip cause, run time | ||||
Current amplitude display stick | Operating current as a percentage of the set current is displayed | |||||
installation | Panel Mounting (3DM2/3MZ2) | |||||
Flush mounting (FDM2/FMZ2) | ||||||
insulation | Between the outer casing and the line | Over DC500V 10MΩ | ||||
Compressive strength | Between the outer casing and the line | 2kV, 50/60Hz, 1 minute. | ||||
Split grounding room | 1kV, 50/60Hz, 1 minute. | |||||
Line room | 2kV, 50/60Hz, 1 minute. | |||||
Electrostatic discharge (ESD) | IEC61000-4-2 | Discharge in air: ±8kv, terminal discharge: ±6kv | ||||
Electromagnetic radiation interference | IEC61000-4-3 | Third level: 10v/m, 80~1000MHZ | ||||
Electromagnetic discharge | IEC61000-4-6 | Third level: 10V, 0.15~80MHz | ||||
EFT/Burst | lEC61000-4-4 | Third level: ±2kv, 1 minute | ||||
surge | IEC61000-4-5 | Third level: 1.2 x 50μs, 4KV (0°, 90°, 180°, 270°) | ||||
Conducted interference | CISPR11 | Class A (conduction and radiation) | ||||
surroundings | temperature | Storage | -40°C ~ 85°C | |||
jobs | -20°C ~ 60°C | |||||
humidity | 30~85% RH without condensation | |||||
weight | 3DM2 / 3MZ2 | FDM2 / FMZ2 | ||||
Window type | 265g | 350g | ||||
Through Bottom hole type | 295g | 390g | ||||
Terminal type | 295 120 = 415g | 390 120 = 510g | ||||
Display section (W/3M cable) | 125g | |||||
Power consumption | Less than 7VA. |
Sản phẩm liên quan
-
1,900,000.00VND
-
4,300,000.00VND
-
1,600,000.00VND
-
1,200,000.00VND
-
450,000.00VND
-
600,000.00VND
Sản phẩm mới nhất
-
6,350,000.00VND
-
2,550,000.00VND
-
2,550,000.00VND
-
2,550,000.00VND
-
1,750,000.00VND
-
3,500,000.00VND
Sản phẩm khiến mãi
-
6,350,000.00VND
-
2,550,000.00VND
-
2,550,000.00VND
-
2,550,000.00VND
-
1,750,000.00VND
-
3,500,000.00VND
Đánh giá
Chưa có đánh giá nào.